Model
|
6605
|
6610
|
6620
|
6630
|
6650
|
INPUT
|
Phase
|
1Ф
|
Voltage
|
110 / 220Vac±10%
|
220±10%
|
Frequency
|
47 - 63Hz
|
Max. Current
|
10A / 5A
|
20A / 10A
|
20A
|
30A
|
50A
|
Power Factor
|
0.7
|
AC OUTPUT
|
Max. Power
|
500VA
|
1000VA
|
2000VA
|
3000VA
|
5000VA
|
Max. Current (r.m.s)*1
|
0-150V
|
4.6A
|
9.2A
|
18.4A
|
27.6A
|
46.0A
|
0-300V
|
2.3A
|
4.6A
|
9.2A
|
13.8A
|
23.0A
|
Max. Current(peak)
|
0-150V
|
18.4A
|
36.8A
|
73.6A
|
110.4A
|
184.0A
|
0-300V
|
9.2A
|
18.4A
|
36.8A
|
55.2A
|
92.0A
|
Phase
|
1Ф / 2W
|
Total Harmonic Distortation (T.H.D)
|
<0.5% 40="" 101="" at="" -="" 100hz,="" <1%="" 500hz="" (resistive="" load)="" <="" td="">
|
Crest Factor
|
≧3
|
Line Regulation
|
± 0.1V
|
Load Regulation
|
± (0.5% of output +0.5V) at Resistive Load
|
Response Time
|
<400µsec <="" td="">
|
SETTINGS
|
Voltage
|
Range
|
0-300V, 150V / 300V Auto Range
|
Resolution
|
0.1V
|
Accuracy
|
±(1% of setting + 2counts)
|
±(1% of setting + 5counts)
|
Frequency
|
Range
|
40-500Hz Full Range Adjust
|
Resolution
|
0.1Hz at 40.0-99.9Hz , 1Hz at 100-500Hz
|
Accuracy
|
±0.03% of setting
|
Starting& Ending
Phase Angle
|
Range
|
0-359°
|
Resolution
|
1°
|
Accuracy
|
±1°(45 - 65HZ)
|
DC OUTPUT (Option)
|
MAX. Power
|
250W
|
500W
|
1000W
|
1500W
|
2500W
|
Max. Current
|
0-200V
|
2.3A
|
4.6A
|
9.2A
|
13.8A
|
23.0A
|
0-400V
|
1.15A
|
2.3A
|
4.6A
|
6.9A
|
11.5A
|
SETTING
|
Voltage
|
Range
|
0-200V / 0-400V Selectable
|
Resolution
|
0.1V
|
Accuracy
|
±(1% of reading + 2counts)
|
±(1% of reading + 5counts)
|
Ripple and Noise (r.m.s)
|
Range
|
L
|
< 250mV
|
< 350mV
|
H
|
< 400mV
|
< 550mV
|
Ripple and Noise (p-p)
|
<2vp-p <="" td="">
|
<3.0vp-p <="" td="">
|
MEASUREMENT
|
Voltage (AC & DC)
|
Range
|
0.0-400.0V
|
Resolution
|
0.1V
|
Accuracy
|
±(1% of reading + 2counts)
|
±(1% of reading + 5counts)
|
Frequency
|
Range
|
0.0-500.0Hz
|
Resolution
|
0.1Hz
|
Accuracy
|
±0.1Hz
|
Current (r.m.s)
|
Range
|
L
|
0.005A - 0.600A
|
0.005A - 1.200A
|
0.005A - 2.400A
|
0.005A - 3.600A
|
-
|
H
|
0.50A -6.50A
|
1.00A -13.00A
|
2.00A -26.00A
|
3.00A - 39.00A
|
0.00 - 65.00A
|
Resolution
|
L
|
0.001A
|
H
|
0.01A
|
Accuracy
|
L
|
±(1% of reading +5counts)
|
± (1% of reading + 5 counts) at 40 - 100Hz
± (2% of reading + 5 counts) at 101 - 500Hz
|
H
|
±(1% of reading +5counts)
|
Current(peak)
|
Range
|
0.0 - 19.0A
|
0.0 - 38.0A
|
0.0 - 76.0A
|
0.0 - 114.0A
|
0.0 - 190.0A
|
Resolution
|
0.1A
|
Accuracy
|
±(1% of reading + 5counts)
|
Current (DC)
|
Range
|
L
|
0.010A - 0.600A
|
0.010A - 1.200A
|
0.010A - 2.400A
|
0.010A - 3.600A
|
-
|
H
|
0.50A - 6.50A
|
1.00A - 13.00A
|
2.00A - 26.00A
|
3.00A - 39.00A
|
0.05A - 65.00A
|
Resolution
|
L
|
0.001A
|
H
|
0.01A
|
Accuracy
|
L
|
± (1% of reading + 5 counts)
|
H
|
± (1% of reading + 5 counts)
|
Power (AC)
|
Range
|
L
|
0.0W - 60.0W
|
0.0W - 120.0W
|
0.0W - 240.0W
|
0.0W - 360W
|
-
|
H
|
50W - 650W
|
100W - 1300W
|
200W - 2600W
|
300 - 3900W
|
0 - 6500W
|
Resolution
|
L
|
0.1W
|
H
|
1W
|
Accuracy
|
L
|
± (2% of reading + 15 counts)
|
± (2% of reading + 30 counts)
|
± (2% of reading + 15 counts) at PF>=0.2 and 40 - 100Hz
± (2% of reading + 15 counts) at PF>=0.5 and 101 - 500Hz
|
H
|
± (2% of reading + 5 counts)
|
± (2% of reading + 10 counts)
|
± (2% of reading + 5 counts)
|
Power (DC)
|
Range
|
L
|
0.0W - 60.0W
|
0.0W - 120.0W
|
0.0W - 240.0W
|
0.0W - 360W
|
-
|
H
|
50W - 650W
|
100W - 1300W
|
200W - 2600W
|
300 - 3900W
|
0 - 6500W
|
Resolution
|
L
|
0.1W
|
H
|
1W
|
Accuracy
|
L
|
± (2% of reading + 5 counts)
|
H
|
± (2% of reading + 5 counts)
|
Power Factor
|
Range
|
0.000-1.000
|
Resolution
|
0.001
|
Accuracy
|
W / VA ,Calculated and displayed to three significant digits
|
GENERAL
|
Remote Input Signal Interface(Option)
|
Test, Reset, Recall memory 1 through 7
|
Remote Output Signal
|
Pass, Fail ,Test-in Process
|
Memory
|
50 memories, 9 steps/memory
|
Sync Output Signal
|
DC Level 5V
|
Timer
|
0=Continuous, 0.5-999.9 (Unit: sec, minute, hour selectable)
|
Alarm Volume Setting
|
Range: 0 - 9; 0=OFF, 1 is softest volume, 9 is loudest volume
|
Graphic Display
|
240 x 64 dot resolution Monographic LCD / Contrast 9 Levels 1 - 9
|
Auto loop cycle
|
0=Continuous, OFF, 2~9999
|
Over Current Fold Back
|
On/Off, Setting On when output current over setting Hi-A value it will fold back output voltage to keep constant output current is setting Hi-A value
|
Efficiency
|
≥80%(at Full Load )
|
Protection
|
Over Current, Short Circuit, Over Temperature, Over Voltage, Over Power, and Alarm
|
Calibration
|
Front Panel Calibration
|
Interface (Option)
|
GPIB, USB & RS232, PLC Remote Input Card
|
Operation Environment
|
0-40℃/20-80%RH
|
Dimension, mm*2
|
W
|
430
|
430
|
430
|
430
|
430
|
H
|
89 (115.5)
|
89 (111.5)
|
89 (111.5)
|
223 (245.5)
|
223 (245.5)
|
D
|
400
|
400
|
500
|
500
|
500
|
Net Weight
|
16.5Kg
|
18.2Kg
|
30Kg
|
57Kg
|
65Kg
|
*1 At working voltage 110V / 220V
|
*Product specifications are subject to change without notice.
|
*2 Figure in parentheses are maximum values
|